Flow Meters
Ultrasonic AMR Meter
The Accumax Ultrasonic AMR Meter is a static water meter that measures flow by the ultrasonic transit-time method and reports readings automatically over a LoRa radio module. A full-information LCD shows consumption data and alarm states, and an in-built data logger retains historical records on the meter.
Key specifications
- Line size
- DN15~DN40mm
- Accuracy
- Class 2/B
- Power supply
- 3.6V Lithium
- Media
- Liquid
Key figures transcribed from the datasheet and pending engineering sign-off. Full specifications below.
How it works
Ultrasonic transit-time measurement. The page states the meter measures by the transit time method and carries a LoRa module for long-range automatic meter reading; no transducer configuration, path count, or electronics detail is given.
Features
-
LoRa long-range transmission
An on-board LoRa module allows readings to be transmitted over long range.
-
In-built data logger
Stores history records on the meter for later review.
-
Transit-time ultrasonic technology
Stated by the source as providing accuracy and ultra-reliable metering (no accuracy figure given).
-
Multi communication support
Source states multiple communication options are supported but does not list them.
-
Dedicated daily information details
Daily consumption information is available on the meter.
-
Five alarm indications
Five different alarm indications are provided; the source does not say what the five alarms are.
-
Compact size, easy to install
-
Long battery life
No battery chemistry, capacity, or service life in years is stated.
-
Full-information LCD display
Displays consumption data and alarm states.
Technical specifications
21 values · 5 groups
These values are transcribed from the manufacturer's datasheet and are pending engineering sign-off. Confirm critical figures with Accumax before specifying.
| Measurement | |
|---|---|
| Measuring principle | Transit time ultrasonic technology in order to provide accuracy and ultra-reliable metering |
| Accuracy | Class 2/B |
| Media | Liquid |
| Diameter | DN15~DN40mm |
| Pipe sizes listed in Flow Range table | 15, 20, 25, 32, 40 |
| Flow range table units | Flow Range in m3/H |
| Min. Flow (m3/H) for pipe sizes 15, 20, 25, 32, 40 | 0.00625, 0.01, 0.01575, 0.025, 0.04m3/h |
| Electrical | |
| Power supply | 3.6V Lithium |
| Consumption | <0.2mW |
| Display | LCD 8 digit + prompt |
| Communication | |
| Wired communication | M-BUS, RS485 |
| Protocol | EN1434, Modbus, CJ188 |
| Wireless communication | Lora : 868MHz |
| Communication support | Multi communication support |
| Long range transmission | Long range transmission through LORA module |
| Environmental | |
| Maximum working pressure | 1.6MPa |
| Protection grade | IP68 |
| Temperature grade | T30/T50/T90 |
| Data & alarms | |
| Data logging | In-built data logger for history record |
| Daily information | Dedicated daily information details availability |
| Alarms | Different 5 Alarm indication |
Source: UFM_AMR_BROCHURE_WO_VALVE
1 further specification is listed in the datasheet but not reproduced here
These labels appear in the datasheet, but the value beside them could not be read reliably from the document. Rather than print a figure we cannot stand behind, we have left them out — ask us and we will confirm them directly.
- Flow Range in m3/H - Max. Flow — the table has 5 pipe-size columns (15, 20, 25, 32, 40) but only 4 Max. Flow cells survived the text layer (3.125, 7.875, 12.5, 20). One cell is lost and the column mapping is unrecoverable, so the Max. Flow row is not published.
Applications
- Industrial R.O. (reverse osmosis) plants
- Residential water metering
- Water supply schemes
- Smart water billing
Frequently asked questions
How does the Ultrasonic AMR Meter measure flow?
It measures by the ultrasonic transit-time method, and shows the readings on a full-information LCD display.
How are readings collected remotely?
The meter uses AMR (automatic meter reading) over an in-built LoRa module for long-range transmission, and the page states that multiple communication options are supported.
Does the meter keep a history of readings if communication is lost?
Yes. The meter has an in-built data logger that retains history records, and dedicated daily information details are available on the meter.
Gallery
Related products
Digital Flow Meter With Telemetry System
Digital flow meter built to CGWA guidelines, with IoT telemetry, cloud dashboard and email/SMS exceedance alerts.
View details
Electromagnetic Flow Meter
Full-bore electromagnetic meter for conductive liquids - no moving parts, no pressure drop, IP66 to IP68 build.
View details
Paddle Wheel Flow Meter
Paddle wheel flow meter from 25 NB with 4-20 mA and RS485 Modbus output and six operating modes.
View details
Need help specifying the right instrument?
Tell us the fluid, line size and accuracy you need. Our engineers will recommend a configuration and quote it.